Morrison Bros. Model 1218S 50 ft. Tank Level Sensor w/ Drop Tube Float

SKU:
MO1218S5010AS
Manufacturer:
Morrison Bros.
Description:
50 ft. Tank Level Sensor w/ Drop Tube Float
Weight:
12.00 LBS
$1,944.36
Adding to cart… The item has been added

The Morrison 1218 electronic tank gauge series monitors and displays the liquid level and/or volume of product stored in 1 to 4 above-ground storage tanks. The tank sensor utilizes a mechanical float to monitor the tank liquid level and electronically converts the tank level to display on the system console located within 1000 ft. of the tank sensor. To order, select a Console Monitor and add it to your cart and then select a Tank Sensor and add it to your cart.

Note: Includes a drop tube float. A 4 in. tank opening is required this model.

System Detail

Configuration Options
  • User defined tank identifications, alarm levels, and input alarm labels
  • Up to 4 programmable liquid level alarm set points per tank
  • Audible alarm ON/OFF and Auto-Silence ON/OFF is programmable by input channel
  • Output relays programmable as normally activated or normally deactivated and for desired alarm activations
  • Email address book supports email and SMS/text message alarm and status notifications
  • Sloped tank and manifold tank functionality available for specific parameters
  • Heartbeat power indicator is user selectable
Network Connectivity
  • Ethernet port connection (RJ-45 connector)
  • TCP/IP configured with static IP address or dynamically using DHCP and local host name
  • HTTPS secure web-based interface with system console for remote viewing
  • Multiple display system consoles can be networked by utilizing Ethernet functionality
Reports
  • System stores an event log (up to 1,000 events) and creates a downloadable report
  • Event log can be downloaded via network Ethernet connection or via USB port inside system console

Features

System Console
  • 4.3 in. diagonal color LCD display (480x272 pixels) with auto LED backlight adjustment
  • System console displays liquid volume level in horizontal, rectangular, or vertical tanks
  • Level units: feet and inches or centimeters (resolution to 1/10 of an inch)
  • Volume units: gallons or liters
  • Visual and audible alarm indication when alarm condition is activated
  • 2 output relays 3 Amps @ 240 VAC
  • Simple push to test or acknowledge alarm button
  • USB port functionality software updates and download event logs
  • Configuration setup via Ethernet PC connection, Ethernet Network connection, or manually at console
  • NEMA 4X indoor/outdoor weather protected, lockable enclosure
  • Optional remote secondary console with operational functionality
Tank Sensor
  • 25 ft. and 50 ft. models available for use with system console
  • 2 dry contact, intrinsically safe inputs available in tank sensor for additional simple switch inputs
  • 25 ft. tank sensor accuracy +/- 0.3 in.; 50 ft. tank sensor accuracy +/- 0.6 in.

Specifications

  • Operating temperature Range: -40°F to 140°F (-40°C to 60°C)
  • Humidity: 0% to 95% non-condensing
  • System console dimensions (H x W x D): 9 3/8 in. x 7 7/8 in. x 4 5/8 in.
  • 100-240 VAC +/- 10%, 50/60 Hz
  • Tank sensor body: Anodized aluminum
  • Cable and float: Stainless steel cable and float
  • Console enclosure: Polycarbonate plastic
  • UL/cUL 913; Listing for Tank Monitoring Equipment for Ordinary Location with Hazardous Location Intrinsically Safe Input Circuits for Class I, Division 1, Group D; Florida DEP EQ-872