Liquip 712 Jump-On API Coupler

SKU:
N/A
Manufacturer:
Weight:
22.00 LBS

These couplers have been discontinued and have been superseded by part numbers OPWLYNX852 and OPWLYNX852VG. Parts continue to be available through JME.

Liquip 712 Jump-On API Coupler

Liquip 712 Jump-On API Coupler

SKU:
N/A
Manufacturer:
Weight:
22.00 LBS

These couplers have been discontinued and have been superseded by part numbers OPWLYNX852 and OPWLYNX852VG. Parts continue to be available through JME.

Features

  • Stainless-steel outer collar
  • New latching-mechanism greatly improves geometry
  • Automatic-latching mechanism and one-touch disconnect ensures effortless operation
  • Hard-anodized aluminum body for extended life
  • Precision-machined latch spindles ensure superior latch alignment, resulting in fewer drips at disconnection
  • Separate nose and inner-poppet seals prevent high pressure from extruding inner seal
  • Ergonomic loop-and-ball handle eases operation and improves comfort
  • Poppet nose seal is replaceable without removing coupler from service
  • Coupler can be disassembled in 2-3 minutes for maintenance
  • Viton® B70 seals standard with Viton® GFLT seals in stock
  • Additional seal materials available upon request

Specifications

  • Technical Data:
    • API710 has 150mm-long handle, API712 has 200mm-long handle
    • API710VG & API712VG have Viton® GFLT seals – recommended for ethanol blends
  • Test Pressure: 1500kPa (218psi) (15bar) uncoupled Operating Pressure 1000kPa (145psi) (10bar)
  • Max Coupling/Uncoupling Pressure: 550kPa (80psi) (5.5bar)
  • Max Coupled Pressure: 2000kPa (290psi) (20bar)
  • Operating Temperature:
    • -20°C to 80°C (-4°F to 176°F) for Viton® B70 seals
    • -40°C to 60°C (-40°F to 140°F) for Viton® GFLT seals
  • Associated Equipment Liquip 'Velvet Touch' Loading Arms
  • Adjustment: None Required
  • Mounting:
    • By industry standard 100mm (4") TTMA Flange
    • 8 holes Ø11mm on 149mm PCD, 168mm outside diameter (Ø7/16" on 5.8" PCD, 6.6" OD)
    • Use spring washers when mounting coupler as per common industry practice