Flowline EchoTouch® US06 Reflective Ultrasonic Liquid Level Sensor Transmitter, 19.6 Ft. Range, 2 in. NPT, Intrinsically Safe

SKU:
FLWUS06000100
Manufacturer:
Flowline
Size:
2 in. Male NPT
Product Type:
Reflective Ultrasonic Liquid Level Sensor
Material:
PVDF
Weight:
1.45 LBS
$948.75
Adding to cart… The item has been added
EchoTouch® US06 intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 19.6 ft. (6 m) range with a 4-20 mA signal output and is configured via it's integral push button module or Flowline's WebCal software. The non-contact liquid level sensor features a proprietary Reflective Technology™ that delivers reliable measurement in condensing environments. The level sensor is suited for small tanks with non-foaming, non-condensing or high vapor media such as chemicals, oil, water and wastewater. Applications include bulk storage, neutral tank and waste sumps.

Features

  • Available in 19.6 ft.(6 m) measurement range
  • Configuration via push button display or free WebCal software
  • Narrow 3 in. beam width for limited space applications
  • PVDF transducer and aluminum enclosure for corrosive liquids
  • LCD display indicates level in inches, meters or percent of span
  • Automatic temperature compensation provides accurate measurement
  • Reflective Technology offers reliable measures with condensation
  • Fail-safe diagnostics with selectable fail-safe signal outputs

Specifications

  • Range: 8 in. to 19.6 ft. (20 cm to 6 m)
  • 2 in. (5.08 cm) NPT w/o Fob
  • Accuracy: ± 0.2% of range
  • Resolution: 0.079 in. (2 mm)
  • Dead band: 8 in. (20.3 cm)
  • Beam width: 3 in. (7.6 cm)
  • Pressure: 30 PSI (2 bar)
  • Configuration: Push button or WebCal® PC, Windows®, USB 2.0
  • Memory non-volatile
  • Display type: LCD, 6 -digit
  • Supply Voltage: 14-28V DC
  • Loop resistance: 500 ohms max at 24V DC
  • Signal output: 4-20mA, two-wire
  • Signal invert: 4-20mA or 20-4 mA
  • Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
  • Temp comp: Automatic
  • Enclosure rating Type 4X (IP66)
  • Intrinsically safe classification
  • Enclosure material: Aluminum
  • Enclosure vent: Water tight membrane
  • PVDF reflective transducer
  • Process temperature: -40° to 176° F (-40° to 80° C)
  • Ambient temp: -31° to 140° F (-35° to 60° C)
  • Nitrile Rubber mount gasket
  • Approvals: CSA for Canada: Class I, Div 1, Groups A,B,C & D T4; Class II, Div 1, Groups E, F, and G T4; Class III, T135C/ CSA for USA: Class I, Div 1, Groups A,B,C & D T4; Class II, Div 1, Groups E, F, & G T4; Class III, T135C
  • Complies to CE, RoHS