Flowline EchoPod® UG06 Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmitter, 2 in. NPT, 19.6 ft. Range

SKU:
FLWUG06000100
Manufacturer:
Flowline
Size:
2 in. Male NPT
Product Type:
Reflective Ultrasonic Liquid Level Sensor
Material:
PVDF
Weight:
1.75 LBS
$759.00
Adding to cart… The item has been added
EchoPod® UG06 is a non-contact liquid level sensor. The general purpose reflective ultrasonic mulit-function level transmitter provides continuous measurement up to 19.6 ft. with a 4-20 mA analog signal output. It is configured via it is integral push button display module or WebCal software. The non-contact liquid level sensor feature a proprietary Reflective Technology™ that delivers reliable measurement in condensing environments. Unlike flat sensor horizontal surfaces, the EchoPod® transducer is oriented vertically so condensation runs off the transducer and does not affect it's performance. The unimpeded transmit & receive signals are redirected to and from the liquid off an 45° reflector, delivering reliable level measurement. The relay can be configured for alarm, automatic fill and empty functions. The sensor is good for bulk tanks with non-foaming and mild vapor media, such as chemicals, oil, water and wastewater. Applications include: Bulk storage, Neutralization tank, clarifier and Waste Sumps.

Features

  • Offered in 19.6 ft. (6m) range
  • Fail-safe diagnostics with selectable relay and signal outputs
  • Narrow 3 in. (7.6 cm) beam width for limited space applications
  • Corrosion resistant PVDF transduced with IP68 PP enclosure
  • LCD display indicates level in inches, meter or percent of span
  • Automatic temperature compensation from -40° to 176° F (-40° to 80°C)

Specifications

  • 2 in. (5 cm) NPT process mount w/o Fob
  • Range: 8 in. to 19.6 ft.
  • Accuracy: ±0.2 % range
  • Pressure: 30 PSI (2 bar)
  • Configuration: Push button or WebCal® PC Windows® USB 2.0
  • Supply Voltage: 14-28V DC
  • Max Consumption: 0.5 W
  • Loop resistance: 500 ohms @ 24V DC
  • Signal output: 4-20mA, two-wire
  • Signal invert: 4-20mA or 20-4 mA
  • Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
  • Conduit entrance: 1/2 in. NPT
  • Contact rating: 60 VA, 1A max.
  • Contact fail-safe: Open, closed, hold last
  • Cable: 48 in. (1.2 m) L 9-conductor, shielded style
  • PVDF transducer
  • Process temperature: -40° to 176° F (-35° to 60° C)
  • Ambient temp: -31° to 140° F (-35° to 60° C)
  • Nitrile rubber mount gasket
  • Dimensions: 3.33 in. ( 84.6 mm) Face dia. X 6.96 in. (176.7 mm) H
  • UL 61010-1 Approved
  • Complies to CE, RoHS