Winters LIS Intrinsically Safe Pressure Transmitter - 0 - 3600 PSI

SKU:
WILIS395
Manufacturer:
Winters
Range:
0-3600 PSI
Over Pressure:
5802 PSI
Burst Pressure:
7252 PSI
Weight:
2.00 LBS
$827.55
Adding to cart… The item has been added
Appropriate for all hazardous areas where an intrinsically safe rating is required, including oil & gas and chemical installations.

Features

  • Approved for intrinsically-safe applications in Class 1/Div. 1 hazardous areas
  • Rugged stainless steel construction with ceramic sensor
  • Available ranges include in/Hg up to 8,700 psi
  • Wide range of mechanical and electrical connections
  • ±0.5% FSO accuracy
  • NEMA 4X and 6P / IP65, IP67 or IP68
  • Approved for outdoor use
  • Customizable
  • 5 year warranty

Specifications

  • Output Signal: 4-20 mA / Vs = 8-32 Vdc
  • Accuracy: ± 0.5% FSO IEC 60770
  • Permissible Load: Rmax = [(Vs - Vs min) / 0.02] Ohm
  • Influence Effects:
    • Supply: 0.05% FSO / 10 V
    • Load: 0.05% FSO / kOhm
  • Response Time: <10 ms
  • Thermal Error:
    • <±0.2% FSO / 10K
    • In Compensated Range: -13°F to 185°F (-25°C to 85°C)
  • Permissible Temperatures:
    • Medium: -40°F to 257°F (-40°C to 125°C)
    • Electronics Environment: -13°F to 185°F (-25°C to 85°C)
    • Storage: -40°F to 212°F (-40°C to 100°C)
  • Short Circuit Protection: Permanent
  • Reverse Polarity Protection: No damage - No function
  • Electromagnetic Protection: Emission and immunity according to EN 61326
  • I.S. Protection: Class 1, Div. 1, Groups A, B, C & D
  • Stability:
    • Vibration: 10 g RMS (20 to 2,000 Hz)
    • Shock: 500 g / 1 ms
  • Polluiton Degree: 4, electrical equipment for outdoor use
  • Housing: 316L Stainless Steel
  • Pressure Port: 316 L Stainless Steel
  • Wetted Parts:
    • Seals: PN < 1450 psi: FKM70
    • Diaphragm: Ceramic AI2O3 96%
  • Weight: 140 g
  • Current Consumption:
    • Current: 25mA max
    • Voltage: 7 mA max
  • Operating Life: >100 x 10^6 Cycles
  • Connecting Cables:
    • Cable Capacitance: Signal line/shield and signal line/signal line: 160 pF/m
    • Cable Inductance: Signal line/shield and signal line/signal line: 1 uH/m