Emerson Fisher Type R122H 1/4 in. NPT x 1/2 in. NPT Aluminum First-Stage Regulator w/ Non-Adjustable 10 PSIG Spring, 1.1M BTU/HR

SKU:
FIR122HAAJ
Manufacturer:
Emerson Fisher
Size:
1/4 in. x 1/2 in.
Material:
Aluminum
Capacity:
1,100,000 BTU/hr.
Product Type:
First Stage
Weight:
1.50 LBS
$47.37
Adding to cart… The item has been added
The Fisher Type R122H is an UL listed regulator designed for Two-Stage LP-Gas (Propane) systems. The unit is designed for use as a first-stage regulator for domestic applications, perfect for tight installations. Stainless steel internal parts and corrosion resistant coatings provide Recommended Replacement Life of 20 years. Inlet and outlet gauge taps allow easy system testing, even in underground tanks. The outlet pressure set point remains at a nominal factory setting of 10 psig / 0.69 bar.

Features

  • 20 Year Recommended Replacement Life: The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both internally and externally - With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life
  • Dual Gauge Taps: Built in 1/8 inch NPT gauge taps orifice to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing
  • Durability: A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas
  • Improved Regulation - A large fabric reinforced diaphragm and stabilizer clip deliver accurate and stable regulation
  • Easy Installation: The units compact size and easily accessible inlet and outlet wrench flats make installation easy even in the tightest installations
  • Superior Overpressure Protection: The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards - When used in conjunction with a R622 or R652, the two-stage system will limit the downstream pressure from the second stage to 2 psig even in a double failure situation
  • Corrosion-Resistant: Added corrosion resistance from an internal and external coating process for all casting prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat
  • Positive Draining Spring Case: When installed properly with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case

Specifications

  • Capacity (Propane): 1,100,000 BTU/HR (12.4 SCMH)
  • Inlet Connection: 1/4 in. NPT
  • Outlet Connection: 1/2 in. NPT
  • Material: Aluminum
  • Maximum Operating Pressure: 250 psig (17.2 bar)
  • Nominal Outlet Setting: 10 psig (69 bar)
  • Vent Size: 3/8 in. NPT screened
  • Temperature Capabilities: -20° to 160°F (-29° to 71°C)
  • Certifications: UL, CRN
  • Color: Red, for easy identification

Warning

Warning: Failure to follow the instructions or to properly install and maintain this equipment could result in an explosion and/or fire causing property damage and personal injury or death. Fisher® equipment must be installed, operated and maintained in accordance with federal, state and local codes and Fisher instructions. The installation in most states must also comply with NFPA No. 54 and 58 standards. Only personnel trained in the proper procedures, codes, standards and regulations of the LP-Gas industry should install and service this equipment. Buyer agrees that responsibility for proper selection, installation, use and maintenance of any product remains solely with the purchaser and end-user. Buyer agrees to comply with the above warning and all instruction manuals, bulletins and installation guides associated with this product.

Downloads

Product Manual (PDF Download)

Product Bulletin (PDF Download)

Product Schematic (PDF Download)